Product Introduction
JEFFAMINE® M-1000 polyetheramine is a polyether monoamine with an average molecular weight of about 1000. Its PO/EO ratio is 3/19, quite hydrophilic. Waxy solid at room temperature.
CASnumber |
83713 -01-3 |
Molecular formula |
|
Application
• Ore flotation agent.
• Corrosion inhibitors.
• Agrochemical emulsifiers.
• Emulsifier for epoxy resins.
Advantages
• Amino groups are more reactive than alcohols.
• Water solubility is beneficial for many applications.
• Polyether links provide flexibility.
Specifications
Features |
Specifications |
Test Method |
Appearance |
None Color to light yellow, slightly turbid |
ST -30.1 |
Color,Pt-Co |
75 Max. |
ST -30.12 |
Primary amine>
Melting point, °C span>(°F) 29.4 (84.9) |
Operation and Storage
Building Materials - At 75-100°F (34-38°C):
Storage tank |
carbon Steel |
pipes, valves |
carbon Steel |
Pump |
carbon Steel |
Heat exchanger surface |
Stainless steel |
Hose |
Stainless steel , polypropylene, polyethylene and TEFLON®1 |
Shim, packaging |
Acrylic or TEFLON®1(avoid elastomers such as neoprene,Ncloth sodium rubber, VITON®1) |
Gas Environment |
nitrogen or dry air |
· At temperatures above 100°F (38°C):
Storage tank |
Stainless steel or aluminum alloy |
pipes, valves |
Stainless steel |
Pump |
Stainless steel or material equivalent toCarpenter 20 |
Gas Environment |
nitrogen |
JEFFAMINE® M-1000 polyetheramine can be stored for a long time in air at room temperature. However, it is generally recommended to store under a blanket of nitrogen to reduce the risk of accidental exposure to high temperatures and to reduce the absorption of moisture and carbon dioxide from the air. It should be noted that at temperatures above 140°F (60°C), discoloration will occur regardless of the atmosphere in which it is protected. Pipes and equipment coated with JEFFAMINE® M-1000 polyetheramine can be cleaned with warm water or steam. In the event of an accidental release, the area should be flushed with copious amounts of water. The proper way to dispose of waste is by incineration in accordance with relevant federal, state or local regulations.
Affordance
In North America or Asia, samples may be obtained from the Sample Processing Center at 1-800-662-0924. In other regions, including Europe, samples can be requested from a Huntsman sales office.
Storage tank
Stainless steel or aluminum alloy
pipes, valves
Stainless steel
Pump
Stainless steel or material equivalent toCarpenter 20
Gas Environment
nitrogen
JEFFAMINE® M-1000 polyetheramine can be stored for a long time in air at room temperature. However, it is generally recommended to store under a blanket of nitrogen to reduce the risk of accidental exposure to high temperatures and to reduce the absorption of moisture and carbon dioxide from the air. It should be noted that at temperatures above 140°F (60°C), discoloration will occur regardless of the atmosphere in which it is protected. Pipes and equipment coated with JEFFAMINE® M-1000 polyetheramine can be cleaned with warm water or steam. In the event of an accidental release, the area should be flushed with copious amounts of water. The proper way to dispose of waste is by incineration in accordance with relevant federal, state or local regulations.
Affordance