Products Description
Tivida FL 2500 Fluorosurfactant for coating and printing applications.
Specifications
Item |
Specification value |
Method |
Appearance |
colorless to yellow |
Visual Evaluation |
Active Ingredients |
≥ 30 % |
Titration |
pH (1% active ingredient in water ) |
4.0 – 7.0 |
DIN 19268 |
Static Surface Tension (0.1wt% active ingredients in water ) |
≤ 18.9 mN/m |
DIN EN 14370 |
These parameters will be evaluated for each batch and will be reported on the Certificate of Analysis Report
Other Information
Solvent |
1-methoxy 2-propane Alcohol |
Ionic features |
Anions |
Counter ion |
Na+ |
Dosage |
0.005-0.1wt% active ingredient 0.02-0.3wt% products |
foaming behavior (0.1% active ingredient in water) |
Initial 170mm 5min after 165mm |
Dynamic Surface Tension (0.1% active ingredient in water) |
~63.2mN/m(0.1s Bubble life) ~34.1mN/m (1s bubble Life) ~26.5mN/m (60s bubbles Life) |
Static Surface Tension (active ingredients in water) |
~ 17.9 mN/m (1 wt %) ~ 18.1 mN/m (0.1 wt %) |
critical micelle concentration |
~ 0.1 wt % |
Density at 20°C |
1.20 g/ml |
hlb value |
42 |
Storage period |
12 months (under evaluation; may be more long time) |
package size |
50g, 1kg, 25 kg |
Ecology Friendly
Contains, does not originate from, and will not degrade to PFOS, PFOA, or other substances listed in the "Preliminary List of PFOS, PFAS, PFOA, PFCA" (2007 revision).
Will not degrade into ≥C4 perfluoroalkanoic acid or sulfonic acid
Therefore, Tivida FL products are not subject to REACH restrictions on PFOA, especially after 2020, Tivida FL can continue to be used in the EU market
Tivida FL 2300 and 2500 are non-toxic for acute oral administration and non-toxic for acute inhalation; non-toxic to aquatic animals and non-bioaccumulative to aquatic environment
Tivida FL 2300 and 2500 have no mutagenicity in gene mutation test and chromosomal aberration test
Tivida FL products also meet the goals of the US Environmental Protection Agency (EPA) 2010/15 PFOA regulatory program
Compliant with Section 6.f) of the EU Standard for Electronic Labeling of Paints and Varnishes (Interior and Exterior Applications) published 13.08.2008.
Disposal: Do not release into the environment (refer to MSDS for details)
��Long time)package size
50g, 1kg, 25 kg
Ecology Friendly
Contains, does not originate from, and will not degrade to PFOS, PFOA, or other substances listed in the "Preliminary List of PFOS, PFAS, PFOA, PFCA" (2007 revision).
Will not degrade into ≥C4 perfluoroalkanoic acid or sulfonic acid
Therefore, Tivida FL products are not subject to REACH restrictions on PFOA, especially after 2020, Tivida FL can continue to be used in the EU market
Tivida FL 2300 and 2500 are non-toxic for acute oral administration and non-toxic for acute inhalation; non-toxic to aquatic animals and non-bioaccumulative to aquatic environment
Tivida FL 2300 and 2500 have no mutagenicity in gene mutation test and chromosomal aberration test
Tivida FL products also meet the goals of the US Environmental Protection Agency (EPA) 2010/15 PFOA regulatory program
Compliant with Section 6.f) of the EU Standard for Electronic Labeling of Paints and Varnishes (Interior and Exterior Applications) published 13.08.2008.
Disposal: Do not release into the environment (refer to MSDS for details)